Melting Point Apparatus Manufacturer,Supplier and Exporter in India

Melting Point Apparatus

Product Code : EDS-CLE-11004

Jainco Export is a leading Melting Point Apparatus Manufacturer,and suppliers in India, Melting Point Apparatus Uruguay (Montevideo), Melting Point Apparatus Uzbekistan (Tashkent), Melting Point Apparatus Venezuela (Caracas), Melting Point Apparatus Vietnam (Hanoi), Melting Point Apparatus Yemen (Sana'a), Melting Point Apparatus Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

The heating rate can be adjusted manually between 1 to 20°C/min, and for rapid heating Jainco Export 10°C/min, to obtain an accurate melting point range. 
The sample and melt process can be viewed via the magnifying lens, which is illuminated by bright LEDs. 
The measures the melting point of chemicals from ambient to 250°C. 
Jainco Export Samples need to be placed in a sealed end capillary tube and located in the heating block. 
Up to three tubes can be tested at one time. 
Record the melt temperatures from the thermometer, positioned horizontal to the samples to allow simultaneous viewing. 
The lens can be detached for cleaning and simple to follow instructions are printed directly on to the unit, making it easy for students to use. 
For 220/240V. 
Dimensions (L x W x H): 370 x 140 x 110 mm.

   