Jainco Export is a leading Drum, sterilizing, 340mm Manufacturer,and suppliers in India, Drum, sterilizing, 340mm Uruguay (Montevideo), Drum, sterilizing, 340mm Uzbekistan (Tashkent), Drum, sterilizing, 340mm Venezuela (Caracas), Drum, sterilizing, 340mm Vietnam (Hanoi), Drum, sterilizing, 340mm Yemen (Sana'a), Drum, sterilizing, 340mm Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

General Description
Drum, sterilizing, 340mm diameter.

Technical Specifications :-
Drum should have an effective closing lid with a clip lock, a carrying handle, air vents system to allow steam to circulate freely during the sterilisation cycle.
Vents to be manually closed after sterilisation.
Cylindrical container used to sterilise dressing materials, surgical instruments, surgical gowns, towels and other reusable medical devices, in a steam sterilizer (autoclave), and to keep them as sterile products for medical activities.
Air vent system (opening and closure mechanism) must be easy to operate and efficient.
Lateral air vents system is preferable to top and bottom air vents.

Material : Austenitic stainless steel, smooth surface.
Austenitic stainless steel composition: approximately 8 to 10% nickel, 18 to 20% chromium.
External diameter : approximately 340 to 350mm.
Height : approximately 180 to 200mm.
Thickness : approximately 0.6 to 0.7mm.

Instructions for use :-
Cylindrical container used to sterilise dressing materials, surgical instruments, surgical gowns and towels and other reusable medical devices,in a steam sterilizer (autoclave), and to keep them as sterile products for medical activities.
The size has been chosen as being the most commonly used for the purpose of use.
The sizes have been chosen taking into consideration different types of steam sterilizers (capacity and internal dimensions), in which this container will be used, to optimise sterilisation activities.
Open air vents system for sterilisation process.
When the sterilisation cycle is completed, close air vents system immediately when the drum is removed from the autoclave.
Do not stuff the drum full with compress or cotton, as the pressurised steam will not be able to penetrate into the centre and therefore not sterilise.


   