Photometer, Glucose 201 Manufacturer,Supplier and Exporter in India

Photometer, Glucose 201

Product Code : EL-LI-12016

Jainco Export is a leading Photometer, Glucose 201 Manufacturer,and suppliers in India, Photometer, Glucose 201 Uruguay (Montevideo), Photometer, Glucose 201 Uzbekistan (Tashkent), Photometer, Glucose 201 Venezuela (Caracas), Photometer, Glucose 201 Vietnam (Hanoi), Photometer, Glucose 201 Yemen (Sana'a), Photometer, Glucose 201 Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

General Description
Hand-held, glucose photometer Glucose 201+, starter set.

Product Description
Multi-wavelength photometric measurement at chemical reaction end-point (667 nm - maxi absorbance point, and 840 nm - turbidity compensation).
Automated point-of-care device for measuring glucose in capillary whole blood.
Technology : optical absorption and reflectance photometry.

Provides direct reading from inserted micro-cuvette.
Removable microcuvette holder to allow for easy cleaning.
Correlation with reference laboratory measurements : 0.99
Factory calibrated and continuous built-in auto self-test (when switched on). 
Needs no further calibration.
Built-in memory, storing > 400 measurements.
Interfaces : RS 232 to printer or computer.
Power supply : 220V /50 or 4 x type AA / R6 1.5 V batteries (allowing for 100h to 150h continued usage).
Read-out in : mg/dL or mmol/L.
Reading time : 40 sec. to 4 min.
Display informs : glucose reading, reading errors, systems errors, battery status.
Symbols in display facilitate multi-lingual understanding.
Sample size : 5 to 10uL capillary, venous or arterial whole blood.
Sample collected directly from skin surface into single-use microcuvette by capillary action.
Uses dedicated microcuvette .
Measuring range : 0 to 500 mg/dL.

Instructions for use
Automated point-of-care device for screening, diagnosing or monitoring blood glucose levels in capillary whole blood.
Used at primary health levels, and for neonatal care.


   